Description
Brief introduction:
ADAM-6251 is a Modbus TCP module that provides 16 digital input channels, integrated with 2 additional 10/100 Base-TX Ethernet ports.
Powered by Peer-to-Peer (P2P) networking and Graphic Conditional Logic graphics, the ADAM-6251 can function as a stand-alone instrument for measurement, control and automation, as well as configurability. group to set up many other modules.
Through internet technology, this compact module can also monitor and remotely control mobile devices.
Industry standard design, support for multiple protocols Modbus/TCP, TCP/IP, UDP, HTTP, DHCP, SNMP, MQTT and XML, HTML5, Javascript, ADAM-6251 web language as an I/O solution integrated in the Ethernet control system.
Specifications:
Digital Input | |
Channels | 16 |
Dry Contact | Logic 0: Open Logic 1: Closed to DGND |
Wet Contact | Logic 0: 0 ~ 3 VDC or 0 ~ -3 VDC Logic 1: 10 ~ 30 VDC or -10 ~ -30 VDC (Dry/Wet Contact decided by Switch) |
Input Impedance | 5.2 kW (Wet Contact) |
Transition Time | 0.2 ms |
Frequency Input Range | 0.1 ~ 3kHz |
Counter Input | 3kHz (32 bit + 1 bit overflow) |
Keep/Discard Counter Value when power off | |
Supports Inverted DI Status | |
Ordering Information | |
ADAM-6251 | 16-ch Isolated Digital Input Modbus TCP Module |
General | |
Cerification | CE,FCC,UL |
Ethernet | 2-port 10/100 Base-TX (for Daisy Chain) |
LED Indication | 16 DI |
Protocol | Modbus/TCP, TCP/IP, UDP, HTTP, DHCP, MQTT, SNMP |
Connector | Plug-in 5P/15P screw terminal blocks |
Power Input | 10 – 30 VDC (24 VDC standard) |
Watchdog Timer | System (1.6 seconds) Communication (Programmable) |
Dimensions | 70 x 122 x 27 mm |
Protection | Built-in TVS/ESD protection Power Reversal protection Over Voltage protection: +/- 35VDC Isolation protection: 2500 VDC |
Power Consumption | 2.7 W @ 24 VDC |
Features | |
Daisy chain connection with auto-bypass protection | |
Remote monitoring and control with smart phone/pad | |
Group configuration capability for multiple module setup | |
DI/O LED Indication | |
Flexible user-defined Modbus address. | |
Intelligent control ability by Peer-to-Peer and GCL function | |
Multiple protocol support: Modbus/TCP, TCP/IP, UDP, HTTP, DHCP, MQTT, SNMP | |
Web language support: XML, HTML 5, Java Script | |
System configuration backup | |
User Access Control | |
Environment | |
Operating Temperature | -10 ~ 70°C (14 ~ 158°F) -40 ~ 70°C (-40~158°F) (B version) |
Storage Temperature | -20 ~ 80°C (-4 ~ 176°F) -40 ~ 80°C ( -40~176°F) (B version) |
Operating Humidity | 20 ~ 95% RH (non-condensing) |
Storage Humidity | 0 ~ 95% RH (non-condensing) |

Reviews